CSI Division 10, known as Specialties, covers products that support storage, privacy, protection, and everyday functionality in commercial buildings. These include commercial lockers, toilet compartments, certain partition systems, and wall and door protection.
Within the Construction Specifications Institute (CSI) MasterFormat system, each division groups related construction work and products. More specific specification sections identify individual product categories and help project teams define what to supply and install.
For commercial architects, general contractors, project managers, and specifiers, understanding the correct CSI division helps organize construction documents, coordinate product requirements, and prepare accurate bids.
In this blog, we’ll explain what CSI Division 10 covers, which specification sections apply to lockers, partitions, and wall protection, and how the CSI MasterFormat system helps construction teams organize commercial building specs.
| What Is in Division 10 Specialties? Division 10 specialties are generally manufactured, prefabricated items that serve a specific function in a finished building. The exact products depend on the facility, its users, and the project’s specifications, and they fall into seven groups, shown in the table below. |
These classifications appear in Division 10 product directories such as ARCAT. Always verify the applicable section and requirements against the project’s specifications and the MasterFormat edition the project uses, since specifiers sometimes place a product differently.
How Division 10 Is Organized
Before the product groups, Division 10, Specialties (10 00 00) opens with a few administrative sections, including Operation and Maintenance of Specialties (10 01 00), Common Work Results for Specialties (10 05 00), Schedules for Specialties (10 06 00), and Commissioning of Specialties (10 08 00).
| Group | Sections Included |
| 10 10 00 Information Specialties | Visual display units (10 11 00), display cases (10 12 00), directories (10 13 00), signage (10 14 00), telephone specialties (10 17 00), informational kiosks (10 18 00) |
| 10 20 00 Interior Specialties | Compartments and cubicles (10 21 00), partitions (10 22 00), service walls (10 25 00), wall and door protection (10 26 00), toilet, bath and laundry accessories (10 28 00) |
| 10 30 00 Fireplaces and Stoves | Manufactured fireplaces (10 31 00), fireplace specialties (10 32 00), stoves (10 35 00) |
| 10 40 00 Safety Specialties | Emergency access and information cabinets (10 41 00), emergency aid specialties (10 43 00), fire protection specialties (10 44 00) |
| 10 50 00 Storage Specialties | Lockers (10 51 00), postal specialties (10 55 00), storage assemblies (10 56 00), wardrobe and closet specialties (10 57 00) |
| 10 70 00 Exterior Specialties | Exterior protection (10 71 00), protective covers (10 73 00), manufactured exterior specialties (10 74 00), flagpoles (10 75 00) |
| 10 80 00 Other Specialties | Pest control devices (10 81 00), grilles and screens (10 82 00), flags and banners (10 83 00), gas lighting (10 84 00), security mirrors and domes (10 86 00), scales (10 88 00) |
Key Sections for Commercial Specialty Products
Several Division 10 sections are particularly relevant to commercial specialty products. Most fall into two groups: Interior Specialties, which covers compartments and cubicles, partitions, and wall protection, and Storage Specialties, which covers lockers.
| MasterFormat Section | Product Category | Common Applications |
| 10 21 13 | Toilet compartments | Commercial washrooms in offices, schools and healthcare facilities |
| 10 21 16 | Shower and dressing compartments | Locker rooms and aquatic facilities |
| 10 21 23 | Cubicle curtains and track | Hospitals, clinics and care facilities |
| 10 22 00 | Partitions | Wire mesh, operable and other specialty partition systems |
| 10 26 00 | Wall and door protection | Corridors, healthcare and other high-traffic areas |
| 10 28 00 | Toilet, bath and laundry accessories | Restrooms and washrooms |
| 10 51 00 | Lockers | Schools, offices and recreation facilities |
| 10 51 13 | Metal lockers | Schools, breakrooms and commercial and institutional storage |
| 10 51 16 | Wood lockers | Country clubs, spas and executive locker rooms |
| 10 51 23 | Plastic-laminate-clad lockers | Dry, design-forward spaces such as staff areas |
| 10 51 26 | Plastic lockers | Pools, aquatic centers and other wet areas |
| 10 51 53 | Locker room benches | Athletic facilities and changing rooms |
Phenolic lockers are commonly specified under the general Lockers section, 10 51 00, rather than in their own section. These classifications appear in Division 10 product directories such as ARCAT.
Always verify the applicable section and requirements against the project’s specifications and the MasterFormat edition the project uses, since specifiers sometimes place a product differently.
Lockers, Partitions & Wall Protection Under Division 10
Lockers, partitions, and wall protection are among the Division 10 products commercial projects specify most often. Here is where each one sits and what specifiers should document.
Commercial Lockers
Commercial lockers give people designated storage for clothing, bags, uniforms, and equipment in schools, fitness centers, workplaces, healthcare facilities, and recreation centers. Section 10 51 00 covers lockers, with more specific sections for materials and types.
Specifiers should document moisture exposure, dimensions, configurations, materials, finishes, locks, ventilation, and installation requirements.
Toilet Compartments & Partitions
Section 10 21 13 generally covers toilet compartments for commercial washrooms, Section 10 21 16 covers shower and dressing compartments for changing areas and aquatic facilities, and Section 10 22 00 covers partitions. These categories aren’t interchangeable.
The correct CSI division and specification section depend on the system being specified, and clear classification helps contractors define scope and coordinate dimensions, finishes, hardware, and installation.
Wall & Door Protection
Section 10 26 00 generally covers wall and door protection: products that reduce damage from carts, equipment, and furniture in high-traffic spaces, such as protective panels, corner guards, and wall guards. Consider anticipated impact, material, finish, coverage, mounting method, and coordination with adjacent surfaces.
Locker Room Benches
Section 10 51 53 covers benches for changing rooms and athletic facilities. Specify dimensions, materials, finishes, mounting, and suitability for the environment.
| What Is CSI MasterFormat in Construction? CSI MasterFormat is a standardized system for organizing construction specifications and project information. It gives architects, contractors, engineers, and product suppliers one shared structure for documenting materials, products, and work requirements. |
Information is sorted into divisions and more detailed specification sections. That makes requirements easier to find, scope easier to communicate, and trades easier to coordinate. For example, Division 10 is the broad category of specialties, Section 10 51 00 narrows it to lockers, and Section 10 51 13 identifies metal lockers specifically.
The hierarchy matters because a CSI division alone doesn’t specify a product. The division sets the category, while the section and project documents define the product, performance requirements, materials, finishes, accessories, and installation.
CSI Divisions vs Specification Sections
- Division: Groups related construction work or product categories.
- Specification section: Identifies a specific product category or scope of work.
- Project specification: Defines the requirements the selected product and installation must meet.
A contractor sourcing lockers needs to review the locker section and the project’s own requirements, not just Division 10. Treating a broad classification as a complete product specification.
Importance of CSI Classification in Commercial Building Specifications

Correct classification helps project teams turn product requirements into clearly documented scopes of work. It also supports coordination between design teams, general contractors, subcontractors, and suppliers.
Better Scope Definition
A correctly identified specification section clarifies which products are included in a project and which requirements apply. This is particularly important when multiple specialty products are installed in the same area.
Accurate Bidding
Contractors use specifications to determine the products, materials, accessories, and installation work included in their bids. Clear requirements help reduce ambiguity and make proposed solutions easier to compare.
Smoother Project Coordination
Specialty products may need to align with room layouts, plumbing fixtures, doors, flooring, wall finishes, and other building elements. Early coordination helps identify dimensional conflicts and installation requirements before work begins.
Easier Product Sourcing
A clearly identified section helps suppliers understand the product category the project requires. The detailed specification then provides the criteria needed to assess suitable products and supporting technical documentation.
Consistent Documentation
Construction specification standards provide a common framework for organizing project information. Using the appropriate CSI division and section helps keep drawings, schedules, specifications, bids, and procurement documents consistent.
Project teams must still evaluate performance, materials, dimensions, finishes, accessories, and installation requirements.
How GSS Supports Division 10 Specialty Projects
Granite State Specialties (GSS) supplies and installs Division 10 (even 11 and 12) specialty construction products, including toilet partitions, lockers, benches and shelving, wall protection, window treatments, and hospital curtains.
Window treatments are specified in Division 12, Furnishings (Section 12 20 00), so a single project can touch both divisions. Locker systems come from PENCO, Scranton Products, Hollman, Hadrian, and ASI Storage.
Our MasterFormat Division 10 guide covers every category in more detail.
Working with Granite State Specialties product divisions (Divisions 10, 11, and 12) starts with identifying the required products, confirming the specification sections, and coordinating the details that affect selection and installation. For lockers, partitions, and wall protection, GSS helps teams with each step:
- Match products to spec sections before bids go out.
- Settle dimensions, finishes, hardware, and mounting early.
- Plan locker room layouts with space planning and CAD layout.
- Install with trained crews with 30+ hours of OSHA training.
- Keep one team accountable for estimating, submittals, project management, and installation.
Get Your Commercial Specialty Project Started With GSS

Understanding the correct CSI division helps construction teams organize product requirements and coordinate specialty installations. Division 10, Specialties, is the primary category to review for commercial lockers, toilet compartments, certain partition systems, and wall and door protection.
Next, identify the applicable specification section and document the requirements that matter to the project. Materials, dimensions, finishes, hardware, performance, and installation details all contribute to a complete specification.
For commercial architects, general contractors, project managers, and specifiers, clear classification supports more consistent documentation, more informed product sourcing, and smoother coordination during construction.
Contact Granite State Specialties to discuss your commercial specialty product requirements and installation needs.
FAQs
What is CSI Division 10?
CSI Division 10 is called Specialties in the MasterFormat system. It includes product categories such as lockers, toilet compartments, certain partition systems, and wall and door protection.
Which CSI section covers commercial lockers?
Section 10 51 00 generally covers lockers. More specific sections identify certain types, including metal lockers under Section 10 51 13 and plastic lockers under Section 10 51 26.
Confirm the applicable classification against the project specifications.
Which CSI section covers toilet partitions?
Toilet compartments generally fall under Section 10 21 13 within Division 10. Shower and dressing compartments are generally covered under Section 10 21 16. Other partition systems may use different sections depending on their function.
Which CSI section covers wall protection?
Wall and door protection generally falls under Section 10 26 00. The project specification should identify the required product, materials, coverage, finish, and installation method.
What is the difference between CSI MasterFormat and CSI divisions?
MasterFormat is the overall system that organizes construction specifications. CSI divisions are its broad categories, while individual specification sections identify more specific products or scopes of work.
